The capabilities of MAnorm2 result primarily from two basic utilities implemented in it. One is for the normalization of ChIP-seq samples, and the other is for modeling the mean-variance trend associated with normalized ChIP-seq signal intensities. Several downstream analyses could be performed based on these two utilities, including
We’d like to emphasize here that each of the above analyses takes advantage of the observed mean-variance trend to improve the assessment of within-group variability (i.e., the variation of ChIP-seq signals across samples of the same group). In practice, the strategy could compensate for the lack of sufficient replicates for accurately assessing within-group variability.
For employing the machinery implemented in MAnorm2, you need to
prepare a table that profiles the ChIP-seq signal in each of a list of
genomic intervals for each of a set of ChIP-seq samples. The
H3K27Ac dataset bundled with MAnorm2 provides such an
instance:
#> MAnorm2 1.2.2 2022-10-28
#> chrom start end GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> 1 chr1 29023 29346 8 16
#> 2 chr1 712983 715873 440 498
#> 3 chr1 740056 741095 81 54
#> 4 chr1 751252 753001 2 139
#> 5 chr1 760716 764177 234 329
#> 6 chr1 800556 801985 4 26
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt GM12892_H3K27Ac_2.read_cnt
#> 1 9 23 22
#> 2 477 439 508
#> 3 39 44 40
#> 4 84 11 11
#> 5 350 326 376
#> 6 59 16 19
#> GM12890_H3K27Ac_1.occupancy GM12891_H3K27Ac_1.occupancy GM12891_H3K27Ac_2.occupancy
#> 1 0 0 0
#> 2 1 1 1
#> 3 1 0 0
#> 4 0 1 0
#> 5 1 1 1
#> 6 0 0 1
#> GM12892_H3K27Ac_1.occupancy GM12892_H3K27Ac_2.occupancy
#> 1 1 1
#> 2 1 1
#> 3 1 0
#> 4 0 0
#> 5 1 1
#> 6 0 0
To be specific, each row of the above table represents a genomic
interval; each of the read_cnt variables corresponds to a
ChIP-seq sample and records the numbers of reads from the sample that
fall within the genomic intervals (i.e., the raw read counts for the
sample); the occupancy variables correspond to the
read_cnt variables one by one and specify the occupancy
status of each interval in each sample (an occupancy status of 1
indicates that the interval is enriched with reads in the sample). In
practice, the occupancy status of a genomic interval in a certain
ChIP-seq sample could be determined by its overlap with the peaks (Zhang et al. 2008)
of the sample. Note also that MAnorm2 refers to an interval as occupied
by a sample if the interval is enriched with reads in the sample.
MAnorm2_utils is specifically designed to coordinate with MAnorm2, and we strongly recommend using it to create input tables of MAnorm2.
Note also that, although the above table records raw read counts, MAnorm2 does not impose a restriction that the input measurements of ChIP-seq signals must be integers (see also the section of Continuous Distribution below).
Although MAnorm2 has been designed to process ChIP-seq data, it could be applied in principle to the analysis of any type of data with a similar structure, including DNase-seq, ATAC-seq and RNA-seq data. The only problem associated with such extensions is how to naturally define “peaks” for specific data types.
Most of the peak callers originally devised for ChIP-seq data (e.g., MACS 1.4) also work for DNase-seq and ATAC-seq data. For RNA-seq data, each row of the input table should stand for a gene, and we recommend setting a cutoff (e.g., 20) of raw read count to define “peak” genes.
In spite of the discrete nature of read counts, MAnorm2 uses continuous distribution to model ChIP-seq data by first transforming raw read counts into raw signal intensities. By default, MAnorm2 completes the transformation by simply adding an offset count to each raw count and taking a base-2 logarithm. Practical ChIP-seq data sets, however, may be associated with various confounding factors, including batch effects, local sequence compositions and background signals measured by input samples. On this account, the MAnorm2 machinery has been designed to be independent of the specific transformation employed. And any methods for correcting for confounding factors could be applied before invoking MAnorm2, as long as the resulting signal intensities could be approximately modeled as following the normal distribution (in particular, consider carefully whether it is necessary to apply a logarithmic transformation in the final step). In the extreme case, you can even accomplish the normalization of ChIP-seq data by yourself and use MAnorm2, for example, only for the following differential analysis.
The primary reason for which MAnorm2 models ChIP-seq signals as continuous random variables is that the mathematical theory of count distributions is far less tractable than that of the normal distribution. For example, current statistical methods based on the negative binomial distribution are frequently relied on approximations of various kinds. Specifically, variance (or dispersion) estimates for individual genomic intervals are typically treated as known parameters, and their uncertainty can hardly be incorporated into the statistical tests for identifying differential signals.
Besides, after an extensive correction for confounding factors, the resulting data range is almost certainly not limited to non-negative integers, and the data may have lost their discrete nature and be more akin to a continuous distribution. Moreover, transforming read counts towards the normal distribution unlocks the application of a large repository of mature statistical methods that are initially developed for analyzing continuous measurements (e.g., intensity data from microarray experiments). Refer to the voom article (Law et al. 2014) for a detailed discussion of this topic.
This section explains in detail the working principle of MAnorm2 and
demonstrates the use of it for various analyses. Note that all
demonstrations are based on the H3K27Ac dataset bundled
with MAnorm2 (see also the section of Input
Data):
#> chrom start end GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> 1 chr1 29023 29346 8 16
#> 2 chr1 712983 715873 440 498
#> 3 chr1 740056 741095 81 54
#> 4 chr1 751252 753001 2 139
#> 5 chr1 760716 764177 234 329
#> 6 chr1 800556 801985 4 26
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt GM12892_H3K27Ac_2.read_cnt
#> 1 9 23 22
#> 2 477 439 508
#> 3 39 44 40
#> 4 84 11 11
#> 5 350 326 376
#> 6 59 16 19
#> GM12890_H3K27Ac_1.occupancy GM12891_H3K27Ac_1.occupancy GM12891_H3K27Ac_2.occupancy
#> 1 0 0 0
#> 2 1 1 1
#> 3 1 0 0
#> 4 0 1 0
#> 5 1 1 1
#> 6 0 0 1
#> GM12892_H3K27Ac_1.occupancy GM12892_H3K27Ac_2.occupancy
#> 1 1 1
#> 2 1 1
#> 3 1 0
#> 4 0 0
#> 5 1 1
#> 6 0 0
This dataset profiles H3K27Ac ChIP-seq signals on a genome wide scale for three human lymphoblastoid cell lines (LCLs), each derived from a separate Caucasian individual (associated ChIP-seq data obtained from (Kasowski et al. 2013)). For meta information regarding these cell lines, type
#> individual population gender cellType
#> 1 GM12890 Caucasian female lymphoblastoid cell line
#> 2 GM12891 Caucasian male lymphoblastoid cell line
#> 3 GM12892 Caucasian female lymphoblastoid cell line
For details about the generation of this dataset, type
?H3K27Ac.
Here we show the standard workflow for a differential ChIP-seq analysis between two groups of samples. We use the comparison between the H3K27Ac ChIP-seq samples for GM12891 LCL and those for GM12892 LCL as example:
# Perform within-group normalization.
norm <- normalize(H3K27Ac, count = 5:6, occupancy = 10:11)
norm <- normalize(norm, count = 7:8, occupancy = 12:13)
# Construct a bioCond for each group of samples.
conds <- list(GM12891 = bioCond(norm[5:6], norm[10:11], name = "GM12891"),
GM12892 = bioCond(norm[7:8], norm[12:13], name = "GM12892"))
# Perform between-group normalization.
# Restrict common peak regions to autosomes only when the two groups
# being compared are associated with different genders.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
conds <- normBioCond(conds, common.peak.regions = autosome)
# Fit a mean-variance curve.
# If the following function call raises an error,
# set init.coef = c(0.1, 10) or try method = "local".
conds <- fitMeanVarCurve(conds, method = "parametric", occupy.only = TRUE)#> During the parametric fit procedure:
#> After iteration 1: coef = (0.0133814, 5.43493); 971 (0.86%) outlier(s) detected
#> After iteration 2: coef = (0.013118, 5.45959); 971 (0.86%) outlier(s) detected
#> After iteration 3: coef = (0.0131117, 5.45988); 971 (0.86%) outlier(s) detected
#> Converged.
#> GM12891.mean GM12892.mean Mval Mval.se Mval.t pval padj
#> 1 2.952943 4.378686 1.4257425 0.6959293 2.0486888 4.049255e-02 7.281479e-02
#> 2 8.594610 8.842037 0.2474271 0.1687811 1.4659641 1.426581e-01 2.131498e-01
#> 3 4.970712 5.282421 0.3117088 0.4302032 0.7245617 4.687210e-01 5.638290e-01
#> 4 6.279446 3.357143 -2.9223031 0.4751332 -6.1504920 7.724294e-10 5.889993e-09
#> 5 8.038011 8.401049 0.3630385 0.1853013 1.9591797 5.009175e-02 8.753281e-02
#> 6 4.733793 4.015697 -0.7180965 0.5494122 -1.3070268 1.912036e-01 2.723929e-01
Note: rows of the above table of differential
analysis results correspond to the genomic intervals in
H3K27Ac one by one with the same order. See also a detailed
explanation below.
MAnorm2 normalizes two individual ChIP-seq samples by removing the overall M-A trend (M and A values refer to log2 fold change and average log2 read count, respectively) associated with their common peak regions, which are the genomic intervals occupied by both of them. For normalization of a set of any number of ChIP-seq samples, MAnorm2 selects one of the samples as baseline and normalizes each other sample against it. Taking the comparison of H3K27Ac ChIP-seq signals between GM12891 and GM12892 LCLs as example, you may choose to normalize all the related samples once for all, by supplying raw read counts and occupancy states associated with the samples:
# One-step normalization.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
norm <- normalize(H3K27Ac, count = 5:8, occupancy = 10:13,
common.peak.regions = autosome)Note: here we exclude the genomic intervals in sex chromosomes from common peak regions, since these ChIP-seq samples are associated with different genders.
By default, MAnorm2 uses the median-ratio strategy (Anders and Huber 2010) to estimate the size
factor of each ChIP-seq sample and selects the sample whose log2 size
factor is closest to 0 as baseline. In practice, you can avoid using a
sample with bad quality as baseline by explicitly specifying the
baseline argument of normalize(). Besides,
when the number of samples to be normalized is large (e.g., >5), you
can reduce the variability of normalization results by setting
baseline to "pseudo-reference", in which case
MAnorm2 constructs a pseudo ChIP-seq profile as baseline by “averaging”
all the samples (type ?normalize for details).
Check some information regarding the performed normalization by
#> [1] "names" "row.names" "metaInfo" "class" "size.factor" "baseline"
#> [7] "norm.coef" "MA.cor"
#> $size.factor
#> GM12891_H3K27Ac_1.read_cnt GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt
#> 1.0914779 1.0854059 0.8836196
#> GM12892_H3K27Ac_2.read_cnt
#> 0.9574468
#>
#> $baseline
#> [1] "GM12892_H3K27Ac_2.read_cnt"
#>
#> $norm.coef
#> slope intercept common.peak.regions
#> GM12891_H3K27Ac_1.read_cnt 1.0211083 -0.4409282 41759
#> GM12891_H3K27Ac_2.read_cnt 1.0264489 -0.4604073 42752
#> GM12892_H3K27Ac_1.read_cnt 0.9562856 0.4758901 46259
#> GM12892_H3K27Ac_2.read_cnt 1.0000000 0.0000000 51554
#>
#> $MA.cor
#> GM12891_H3K27Ac_1.read_cnt GM12891_H3K27Ac_2.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 0.000000000 -0.03017988
#> GM12891_H3K27Ac_2.read_cnt 0.007119437 0.00000000
#> GM12892_H3K27Ac_1.read_cnt 0.016129812 0.01551055
#> GM12892_H3K27Ac_2.read_cnt 0.000000000 0.00000000
#> GM12892_H3K27Ac_1.read_cnt GM12892_H3K27Ac_2.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 0.1035251 0.03699763
#> GM12891_H3K27Ac_2.read_cnt 0.1179751 0.04865985
#> GM12892_H3K27Ac_1.read_cnt 0.0000000 -0.20926760
#> GM12892_H3K27Ac_2.read_cnt 0.0000000 0.00000000
# This statement requires the gplots package (>= 3.0.1).
plot(attr(norm, "MA.cor"), symbreaks = TRUE, margins = c(8, 8),
cexRow = 1, cexCol = 1)The norm.coef attribute records the linear
transformation applied to the log2 read counts of each ChIP-seq sample
as well as the number of common peak regions between each sample and the
baseline. The MA.cor attribute is a matrix recording the
Pearson correlation coefficient (PCC) between M and A values across the
common peak regions of each pair of samples. The upper and lower
triangles of this matrix are calculated from raw and normalized log2
read counts, respectively. In general, it indicates a good normalization
performance that the M-A PCCs are all close to 0 after
normalization.
We can also draw MA plots to visualize the normalization effects. Here we use the two biological replicates of GM12892 LCL as example:
# Before normalization.
raw <- log(H3K27Ac[7:8] + 0.5, base = 2)
MAplot(raw[[1]], raw[[2]], norm[[12]], norm[[13]], ylim = c(-2, 2),
main = "Before normalization")
abline(h = 0, lwd = 2, lty = 5)
# After normalization.
MAplot(norm[[7]], norm[[8]], norm[[12]], norm[[13]], ylim = c(-2, 2),
main = "After normalization")
abline(h = 0, lwd = 2, lty = 5)In comparison to this one-step normalization, we prefer to adopt a hierarchical normalization process that takes advantage of the similarity structure among samples. Specifically, we first separately normalize the samples of each LCL:
# Within-group normalization.
norm <- normalize(H3K27Ac, count = 5:6, occupancy = 10:11)
norm <- normalize(norm, count = 7:8, occupancy = 12:13)The key data type designed by MAnorm2 is bioCond, which
is for grouping ChIP-seq samples belonging to the same biological
condition. We next construct a bioCond object for each LCL
to group its biological replicates, by supplying their normalized signal
intensities and occupancy states:
# Construct a bioCond for each LCL.
conds <- list(GM12891 = bioCond(norm[5:6], norm[10:11], name = "GM12891"),
GM12892 = bioCond(norm[7:8], norm[12:13], name = "GM12892"))Note: bioCond objects do not
design a data field to specifically record the associated genomic
intervals. The list and order of genomic intervals in a
bioCond are the same as with the signal intensities for
constructing it and will never be changed. In principle, all the MAnorm2
functions accepting multiple bioCond objects expect them to
be associated with the same list and order of genomic intervals (e.g.,
normBioCond()), and it is your job to make sure of that.
Note also that all the MAnorm2 functions applying a statistical test to
each individual genomic interval generate a table that is associated
with the same list and order of intervals as with the supplied
bioCond(s) (e.g., diffTest()).
We can summarize a bioCond by
#>
#> Biological condition GM12891:
#> 73828 genomic intervals with 2 profiles
#>
#> Occupancy states:
#> 57577 (78.0%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> -0.9807 6.1390 7.3980 7.2557 8.6744 12.1563
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 7.180e-06 7.194e-02 1.574e-01 2.180e-01 2.927e-01 3.012e+00
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12891_H3K27Ac_1.read_cnt GM12891_H3K27Ac_2.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 1 0
#> GM12891_H3K27Ac_2.read_cnt 0 1
#>
#> The condition is not yet associated with a mean-variance curve.
Note: as indicated in the summary, MAnorm2 defines
the occupancy states of genomic intervals in each bioCond,
which are determined by the number of samples in the
bioCond occupying each interval (see the
occupy.num argument of bioCond()). The
occupancy states of genomic intervals in bioCond objects
matter for the following between-group normalization and mean-variance
curve (MVC) fitting. When the samples to be grouped into a
bioCond are biological replicates for the same experiment,
we recommend using the default setting, which is
occupy.num = 1.
Finally, we normalize the resulting bioCond objects to
make them comparable between each other:
# Between-group normalization.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
conds <- normBioCond(conds, common.peak.regions = autosome)We can also draw MA plots on bioCond objects to
visualize the normalization results:
MAplot(conds[[1]], conds[[2]], ylim = c(-12, 12), main = "GM12891 vs. GM12892")
abline(h = 0, lwd = 2, lty = 5)After normalization, MAnorm2 next models the relationship between mean signal intensities of genomic intervals and their variances by fitting a smooth mean-variance curve (MVC):
# Fit an MVC.
# The "parametric" method sometimes requires the users to explicitly specify
# initial coefficients. Try setting init.coef = c(0.1, 10) in these cases.
conds <- fitMeanVarCurve(conds, method = "parametric", occupy.only = TRUE)#> During the parametric fit procedure:
#> After iteration 1: coef = (0.0133814, 5.43493); 971 (0.86%) outlier(s) detected
#> After iteration 2: coef = (0.013118, 5.45959); 971 (0.86%) outlier(s) detected
#> After iteration 3: coef = (0.0131117, 5.45988); 971 (0.86%) outlier(s) detected
#> Converged.
This function call associates an MVC with each bioCond
in conds. After the call, all bioCond objects
in conds are associated with the same MVC, as indicated by
the MVC ID:
#>
#> Biological condition GM12891:
#> 73828 genomic intervals with 2 profiles
#>
#> Occupancy states:
#> 57577 (78.0%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> -2.005 5.619 6.968 6.815 8.334 12.063
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.0000077 0.0770344 0.1685540 0.2334152 0.3134602 3.2249765
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12891_H3K27Ac_1.read_cnt GM12891_H3K27Ac_2.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 1 0
#> GM12891_H3K27Ac_2.read_cnt 0 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = conds, method = "parametric", occupy.only = TRUE)
#>
#> Summary of the mean-variance curve:
#> Fit method = "parametric fit"
#> ID = "2026-10-05 08:44:50.442359 171YSHOJEU"
#> Number of prior dfs = Inf
#> Variance ratio factor = 1.19
#>
#> Biological condition GM12892:
#> 73828 genomic intervals with 2 profiles
#>
#> Occupancy states:
#> 55567 (75.3%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> -1.269 5.554 6.901 6.860 8.350 12.057
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.0000032 0.0706860 0.1550275 0.2165042 0.2909560 3.2702043
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12892_H3K27Ac_1.read_cnt GM12892_H3K27Ac_2.read_cnt
#> GM12892_H3K27Ac_1.read_cnt 1 0
#> GM12892_H3K27Ac_2.read_cnt 0 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = conds, method = "parametric", occupy.only = TRUE)
#>
#> Summary of the mean-variance curve:
#> Fit method = "parametric fit"
#> ID = "2026-10-05 08:44:50.442359 171YSHOJEU"
#> Number of prior dfs = Inf
#> Variance ratio factor = 0.997
Note: for each bioCond that has been
associated with an MVC, MAnorm2 uses a variance ratio factor to quantify
its global within-group variability (relative to the MVC). When samples
in each bioCond are biological replicates, the
bioCond objects associated with the same MVC should have
similar variance ratio factors. Otherwise, there might be batch effects
and/or samples with bad quality.
To improve the unbiasedness of MVC fitting, MAnorm2 calculates
observed means and variances of genomic intervals separately for each
bioCond, and it pools the resulting mean-variance pairs
from different bioCond objects (after adjusting for
different global within-group variability) into a regression process.
Currently, we provide two candidate methods for the regression process,
which are "parametric fit" and
"local regression". We also design the argument
occupy.only to control whether to use all genomic intervals
or only the occupied ones from each bioCond for the
regression process. In cases where the samples in each
bioCond are biological replicates, the underlying variance
structure could be expected to be very regular, and we recommend using
the "parametric fit" method, with setting
occupy.only to TRUE to further enhance the
data regularity. See the section of Combining
Replicates and Using Local Regression below for an application
scenario of local regression.
The number of prior degrees of freedom is used to assess the overall goodness of fit of the associated MVC. You can also visualize the mean-variance trend along with the MVC by
# Plot only occupied genomic intervals,
# as only these intervals have been used to fit the MVC.
plotMeanVarCurve(conds, subset = "occupied", ylim = c(-7, 0.5))In practice, number of prior degrees of freedom amounts to the number
of additional samples gained by borrowing information between genomic
intervals, and it should be large (relative to the number of
real samples) when samples in each bioCond are
biological replicates.
Finally, we call genomic intervals with differential signal
intensities between the two bioCond objects by
This function call performs a statistical test separately for each
genomic interval, with the null hypothesis that the interval is
non-differential between the supplied two bioCond objects.
It returns a data frame that records the test results for each interval
by each row:
#> GM12891.mean GM12892.mean Mval Mval.se Mval.t pval padj
#> 1 2.952943 4.378686 1.4257425 0.6959293 2.0486888 4.049255e-02 7.281479e-02
#> 2 8.594610 8.842037 0.2474271 0.1687811 1.4659641 1.426581e-01 2.131498e-01
#> 3 4.970712 5.282421 0.3117088 0.4302032 0.7245617 4.687210e-01 5.638290e-01
#> 4 6.279446 3.357143 -2.9223031 0.4751332 -6.1504920 7.724294e-10 5.889993e-09
#> 5 8.038011 8.401049 0.3630385 0.1853013 1.9591797 5.009175e-02 8.753281e-02
#> 6 4.733793 4.015697 -0.7180965 0.5494122 -1.3070268 1.912036e-01 2.723929e-01
In this data frame, Mval could be interpreted as log2
fold change; pval assesses the statistical significance of
each test; padj refers to adjusted p-value with
the "BH" method.
You can visualize the overall test results by
We can see from this figure that differential ChIP-seq signals could be abundant even between very similar cellular contexts.
MAnorm2 compares two individual ChIP-seq samples by treating them as replicates and fitting an MVC based on their common peak regions. This strategy is basically the same as used by DESeq (Anders and Huber 2010). Here we give the standard workflow for comparing two individual ChIP-seq samples. We use the comparison of the first replicates of GM12891 and GM12892 LCLs as example:
# Perform normalization and create bioConds to represent the two LCLs.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
norm <- normalize(H3K27Ac, c(5, 7), c(10, 12), common.peak.regions = autosome)
conds <- list(GM12891 = bioCond(norm[5], norm[10], name = "GM12891"),
GM12892 = bioCond(norm[7], norm[12], name = "GM12892"))
# Create a "blind" bioCond that treats the two samples as replicates and fit an
# MVC accordingly. Only common peak regions of the two samples are considered
# to be occupied by the "blind" bioCond, and only these regions are used to fit
# the MVC. This setting is for capturing underlying non-differential intervals
# as accurately as possible and avoiding over-estimation of prior variances
# (i.e., variances read from MVC).
conds$blind <- bioCond(norm[c(5, 7)], norm[c(10, 12)], occupy.num = 2,
name = "blind")
conds <- fitMeanVarCurve(conds, method = "parametric",
occupy.only = TRUE, init.coef = c(0.1, 10))#> During the parametric fit procedure:
#> After iteration 1: coef = (0.209957, 17.6178); 586 (1.40%) outlier(s) detected
#> After iteration 2: coef = (0.179383, 20.7846); 598 (1.43%) outlier(s) detected
#> After iteration 3: coef = (0.172811, 21.6638); 601 (1.43%) outlier(s) detected
#> After iteration 4: coef = (0.171272, 21.8803); 601 (1.43%) outlier(s) detected
#> After iteration 5: coef = (0.171015, 21.92); 601 (1.43%) outlier(s) detected
#> Converged.
#>
#> Biological condition blind:
#> 73828 genomic intervals with 2 profiles
#>
#> Occupancy states:
#> 41919 (56.8%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> -1.463 5.558 6.841 6.839 8.271 12.060
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.000001 0.195670 0.467627 0.719394 0.960443 8.185305
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12891_H3K27Ac_1.read_cnt GM12892_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 1 0
#> GM12892_H3K27Ac_1.read_cnt 0 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = conds, method = "parametric", occupy.only = TRUE,
#> init.coef = c(0.1, 10))
#>
#> Summary of the mean-variance curve:
#> Fit method = "parametric fit"
#> ID = "2026-10-05 08:44:57.48733 ALVI8EO5ZI"
#> Number of prior dfs = 4.24
#> Variance ratio factor = 0.597
# Visualize mean-variance trend along with the fitted MVC.
plotMeanVarCurve(conds[3], subset = "occupied", ylim = c(-7, 1))#> GM12891.mean GM12892.mean Mval Mval.se Mval.t pval padj
#> 1 3.413499 4.554589 1.14109009 1.3627709 0.8373308 0.44702852 0.8272570
#> 2 8.617834 8.779719 0.16188555 0.5167515 0.3132754 0.76888679 0.9482468
#> 3 5.238002 5.475733 0.23773185 0.9178155 0.2590192 0.80771764 0.9582934
#> 4 6.673159 3.523562 -3.14959737 0.9836902 -3.2018183 0.03025285 0.4549266
#> 5 7.985621 8.350939 0.36531860 0.5431482 0.6725947 0.53610033 0.8689649
#> 6 4.136960 4.044394 -0.09256607 1.3188512 -0.0701869 0.94723279 0.9882270
# Visualize the overall test results.
# We use a cutoff of raw p-value here to select significant intervals.
MAplot(res2, pval = 0.01)
abline(h = 0, lwd = 2, lty = 5, col = "green3")We can see from the last figure a dramatic decrease of statistical power for identifying differential genomic intervals, owing to the lack of true replicates. If you rank intervals in order of statistical significance, however, you will find that this differential analysis without replicates lead to very similar rankings to those from the previous analysis with replicates:
#> [1] 0.9094989
plot(-log10(res$pval), -log10(res2$pval), col = "#0000FF14", pch = 20,
xlab = "With Reps", ylab = "Without Reps")MAnorm2 can also be used to simultaneously compare more than two groups of ChIP-seq samples. Here we give the standard workflow for the cases where at least one of the groups to be compared contains two or more samples. We use the comparison of H3K27Ac ChIP-seq signals among GM12890, GM12891 and GM12892 LCLs as example:
# Perform within-group normalization.
norm <- normalize(H3K27Ac, count = 4, occupancy = 9)
norm <- normalize(norm, count = 5:6, occupancy = 10:11)
norm <- normalize(norm, count = 7:8, occupancy = 12:13)
# Construct a bioCond for each group of samples.
conds <- list(GM12890 = bioCond(norm[4], norm[9], name = "GM12890"),
GM12891 = bioCond(norm[5:6], norm[10:11], name = "GM12891"),
GM12892 = bioCond(norm[7:8], norm[12:13], name = "GM12892"))
# Perform between-group normalization.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
conds <- normBioCond(conds, common.peak.regions = autosome)
# Fit an MVC.
conds <- fitMeanVarCurve(conds, method = "parametric", occupy.only = TRUE)#> During the parametric fit procedure:
#> After iteration 1: coef = (0.0093174, 6.04374); 967 (0.85%) outlier(s) detected
#> After iteration 2: coef = (0.00909686, 6.07412); 968 (0.86%) outlier(s) detected
#> After iteration 3: coef = (0.00908926, 6.07399); 968 (0.86%) outlier(s) detected
#> Converged.
#> conds.mean between.ms within.ms prior.var posterior.var mod.f pval padj
#> 1 3.873144 1.25318002 0.155228311 0.42360573 0.42360573 2.9583642 5.190375e-02 6.438846e-02
#> 2 8.837172 0.02174483 0.003556575 0.02236996 0.02236996 0.9720553 3.783047e-01 4.075928e-01
#> 3 5.845167 0.22961287 0.073940389 0.11474760 0.11474760 2.0010255 1.351966e-01 1.570769e-01
#> 4 3.976759 8.99272048 0.124250239 0.39487900 0.39487900 22.7733572 1.287231e-10 4.506744e-10
#> 5 8.231352 0.15434149 0.004612264 0.02930040 0.02930040 5.2675562 5.156196e-03 7.371500e-03
#> 6 3.993976 2.96216974 0.272820052 0.39030242 0.39030242 7.5894219 5.057734e-04 8.262211e-04
We can see that this workflow is basically the same as that for
two-group comparisons, except the final procedure for performing
differential tests (aovBioCond() is called instead of
diffTest()).
You can visualize the overall test results by
In cases where each group contains a single ChIP-seq sample, try the
strategy of constructing “blind” bioCond objects (see the
section of When No Replicates Are Available)
or calling hypervariable ChIP-seq signals across the samples (see the
section of Identifying Hypervariable ChIP-seq
Signals below).
In practice, chances are that you want to combine biological replicates to get a reference ChIP-seq profile for each biological condition. For example, with ChIP-seq samples for tissues or cells obtained from different individuals, you can classify the individuals according to the age, gender, health status or disease subtype of each of them, and then perform a differential analysis between groups of individuals to identify differential ChIP-seq signals associated with the group characteristics. Suppose that each individual is associated with multiple biological replicates. A reasonable analysis strategy is to separately create a reference profile for each individual by combining the associated biological replicates.
Here we use the comparison of H3K27Ac ChIP-seq signals between male and female LCLs as example to demonstrate how to use MAnorm2 to perform such analyses:
# Use the regular routine for normalization and construction of bioConds.
norm <- normalize(H3K27Ac, count = 4, occupancy = 9)
norm <- normalize(norm, count = 5:6, occupancy = 10:11)
norm <- normalize(norm, count = 7:8, occupancy = 12:13)
conds <- list(GM12890 = bioCond(norm[4], norm[9], name = "GM12890"),
GM12891 = bioCond(norm[5:6], norm[10:11], name = "GM12891"),
GM12892 = bioCond(norm[7:8], norm[12:13], name = "GM12892"))
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
conds <- normBioCond(conds, common.peak.regions = autosome)
# Group LCLs into different genders.
genders <- list(male = cmbBioCond(conds[2], name = "male"),
female = cmbBioCond(conds[c(1, 3)], name = "female"))
# Fit an MVC by using local regression.
genders <- fitMeanVarCurve(genders, method = "local", occupy.only = TRUE)#> During the local regression procedure:
#> After iteration 1: 677 (1.04%) outlier(s) detected
#> After iteration 2: 676 (1.03%) outlier(s) detected
#> After iteration 3: 678 (1.04%) outlier(s) detected
#> After iteration 4: 678 (1.04%) outlier(s) detected
#> After iteration 5: 678 (1.04%) outlier(s) detected
#> Converged.
#>
#> Biological condition female:
#> 73828 genomic intervals with 2 profiles
#>
#> Occupancy states:
#> 65370 (88.5%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> -0.648 5.806 7.026 7.051 8.390 11.725
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.0000058 0.2382255 0.5678519 0.8332772 1.1757849 8.2838812
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12890 GM12892
#> GM12890 1 0
#> GM12892 0 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = genders, method = "local", occupy.only = TRUE)
#>
#> Summary of the mean-variance curve:
#> Fit method = "local regression"
#> ID = "2026-10-05 08:45:12.055117 J84DKX2VQ4"
#> Number of prior dfs = 13.7
#> Variance ratio factor = 0.849
#> male.mean female.mean Mval Mval.se Mval.t pval padj
#> 1 3.655242 3.982095 0.3268530 3.2854629 0.09948461 0.9220941 0.9999813
#> 2 8.763611 8.873952 0.1103400 0.6733359 0.16387073 0.8720590 0.9999813
#> 3 5.482275 6.026613 0.5443382 1.6150539 0.33704026 0.7408384 0.9999813
#> 4 6.667296 2.631490 -4.0358058 2.4714076 -1.63299887 0.1236452 0.9999813
#> 5 8.259626 8.217214 -0.0424119 0.8176631 -0.05186965 0.9593291 0.9999813
#> 6 5.267752 3.357088 -1.9106638 2.7693612 -0.68992945 0.5009591 0.9999813
Note: cmbBioCond() is designed for
combining a list of bioCond objects into a single
bioCond, such that each of the supplied
bioCond objects serves as an individual ChIP-seq sample in
the combined bioCond. Technically, the function integrates
the ChIP-seq samples contained in each bioCond into a
reference ChIP-seq profile and groups the resulting profiles into a new
bioCond object. Note that the argument list of
bioCond objects to cmbBioCond() must be
normalized to be comparable with each other before calling the
function.
Here we use local regression to adaptively capture the mean-variance trend, as the dependence of ChIP-seq signal variability across individual LCLs on mean signal intensity is not as regular as in the previous case for modeling the variability across biological replicates. The above settings for employing local regression should be flexible enough to handle most practical cases. The following are some considerations regarding advanced usage of local regression.
In practice, good chances are that the underlying extrapolation algorithm of local regression results in overestimated prior variances for non-occupied genomic intervals. Naturally, performing the regression on all genomic intervals (rather than only occupied intervals) can avoid the problem:
#> During the local regression procedure:
#> After iteration 1: 797 (1.08%) outlier(s) detected
#> After iteration 2: 797 (1.08%) outlier(s) detected
#> After iteration 3: 798 (1.08%) outlier(s) detected
#> After iteration 4: 798 (1.08%) outlier(s) detected
#> Converged.
plotMeanVarCurve(genders, subset = "non-occupied",
main = "Use occupied intervals")
plotMeanVarCurve(genders2, subset = "non-occupied",
main = "Use all intervals")However, using all genomic intervals to fit MVC may considerably reduce the estimated number of prior degrees of freedom as well as the statistical power for identifying differential intervals, owing to the fact that ChIP-seq signal measurements in non-occupied intervals are generally of less data regularity compared with those in occupied intervals:
#> [1] 13.73788
#> [1] 5.921202
To split the difference, you can perform local regression on all genomic intervals and re-estimate the number of prior degrees of freedom using only occupied intervals:
genders3 <- estimatePriorDf(genders2, occupy.only = TRUE)
plotMeanVarCurve(genders3, subset = "non-occupied",
main = "Re-estimate prior df")#> [1] 8.238743
Note: in fact, when calling
fitMeanVarCurve() to fit an MVC,
estimatePriorDf() is automatically invoked for the
associated parameter estimation. There is also a robust version
of estimatePriorDf(), named
estimatePriorDfRobust(). It renders the estimation
procedure robust to potential outliers by applying the Winsorization
technique (Phipson et al. 2016). Type
?estimatePriorDfRobust for details.
Since MAnorm2 1.1.0, one of the new changes is the implementation of
HyperChIP, which is a method developed for identifying genomic intervals
with hypervariable ChIP-seq signals across a set of samples. Compared
with the old workflow shown in the vignette for MAnorm2 1.0.0, HyperChIP
has made specific efforts to increase the statistical power for
identifying hypervariable intervals (refer to
?estParamHyperChIP for details). Here we use all the
H3K27Ac ChIP-seq samples as an example to demonstrate the standard
workflow of HyperChIP:
# Normalize all ChIP-seq samples once for all.
# Considering the number of samples in a hypervariable ChIP-seq analysis is
# typically large, HyperChIP uses a pseudo-reference profile as baseline in the
# MA normalization process to reduce the variability of normalization results.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
norm <- normalize(H3K27Ac, count = 4:8, occupancy = 9:13,
baseline = "pseudo-reference",
common.peak.regions = autosome)
# Construct a bioCond to group all the samples.
cond <- bioCond(norm[4:8], norm[9:13], occupy.num = 1,
name = "all")
# Fit an MVC by using local regression.
# Set "nn = 1" to increase the smoothness of the resulting MVC.
cond <- fitMeanVarCurve(list(cond), method = "local",
occupy.only = TRUE, args.lp = list(nn = 1))[[1]]#> During the local regression procedure:
#> After iteration 1: 97 (0.13%) outlier(s) detected
#> After iteration 2: 112 (0.15%) outlier(s) detected
#> After iteration 3: 116 (0.16%) outlier(s) detected
#> After iteration 4: 116 (0.16%) outlier(s) detected
#> Converged.
#>
#> Biological condition all:
#> 73828 genomic intervals with 5 profiles
#>
#> Occupancy states:
#> 73821 (100.0%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.6994 5.9455 7.0825 7.1337 8.3771 11.7396
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.01114 0.33134 0.62790 0.80305 1.09181 5.44976
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 1 0
#> GM12891_H3K27Ac_1.read_cnt 0 1
#> GM12891_H3K27Ac_2.read_cnt 0 0
#> GM12892_H3K27Ac_1.read_cnt 0 0
#> GM12892_H3K27Ac_2.read_cnt 0 0
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 0 0
#> GM12891_H3K27Ac_1.read_cnt 0 0
#> GM12891_H3K27Ac_2.read_cnt 1 0
#> GM12892_H3K27Ac_1.read_cnt 0 1
#> GM12892_H3K27Ac_2.read_cnt 0 0
#> GM12892_H3K27Ac_2.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 0
#> GM12891_H3K27Ac_1.read_cnt 0
#> GM12891_H3K27Ac_2.read_cnt 0
#> GM12892_H3K27Ac_1.read_cnt 0
#> GM12892_H3K27Ac_2.read_cnt 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = list(cond), method = "local", occupy.only = TRUE,
#> args.lp = list(nn = 1))
#>
#> Summary of the mean-variance curve:
#> Fit method = "local regression"
#> ID = "2026-10-05 08:45:19.392625 B7TX1FV24U"
#> Number of prior dfs = 2.87
#> Variance ratio factor = 0.446
# Apply the parameter estimation framework of HyperChIP.
# Note the dramatic increase in the estimated number of prior degrees of
# freedom.
cond <- estParamHyperChIP(cond)
summary(cond)#>
#> Biological condition all:
#> 73828 genomic intervals with 5 profiles
#>
#> Occupancy states:
#> 73821 (100.0%) of the genomic intervals occupied by the condition
#>
#> Summary of mean signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.6994 5.9455 7.0825 7.1337 8.3771 11.7396
#>
#> Summary of standard deviations of signal intensities at the genomic intervals:
#> Min. 1st Qu. Median Mean 3rd Qu. Max.
#> 0.01114 0.33134 0.62790 0.80305 1.09181 5.44976
#>
#> The genomic intervals are associated with the same structure matrix:
#> GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 1 0
#> GM12891_H3K27Ac_1.read_cnt 0 1
#> GM12891_H3K27Ac_2.read_cnt 0 0
#> GM12892_H3K27Ac_1.read_cnt 0 0
#> GM12892_H3K27Ac_2.read_cnt 0 0
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 0 0
#> GM12891_H3K27Ac_1.read_cnt 0 0
#> GM12891_H3K27Ac_2.read_cnt 1 0
#> GM12892_H3K27Ac_1.read_cnt 0 1
#> GM12892_H3K27Ac_2.read_cnt 0 0
#> GM12892_H3K27Ac_2.read_cnt
#> GM12890_H3K27Ac_1.read_cnt 0
#> GM12891_H3K27Ac_1.read_cnt 0
#> GM12891_H3K27Ac_2.read_cnt 0
#> GM12892_H3K27Ac_1.read_cnt 0
#> GM12892_H3K27Ac_2.read_cnt 1
#>
#> Function call for associating a mean-variance curve with the condition:
#> fitMeanVarCurve(conds = list(cond), method = "local", occupy.only = TRUE,
#> args.lp = list(nn = 1))
#>
#> Subsequent function call for adjusting related parameters:
#> estParamHyperChIP(cond = cond)
#>
#> Summary of the mean-variance curve:
#> Fit method = "local regression"
#> ID = "2026-10-05 08:45:19.392625 B7TX1FV24U"
#> Number of prior dfs = Inf
#> Variance ratio factor = 1.02
#> observed.mean observed.var prior.var fold.change pval padj
#> 1 4.123172 0.62767325 3.3719506 0.18614545 0.108561188 0.3391233
#> 2 8.835486 0.01362584 0.2844984 0.04789425 0.008610023 0.1013005
#> 3 5.794082 0.16260797 1.4398955 0.11293040 0.043945034 0.2164067
#> 4 4.580327 4.82749982 2.6687559 1.80889526 0.247900708 0.5171521
#> 5 8.302970 0.07726829 0.3872625 0.19952434 0.122594081 0.3598123
#> 6 4.440024 1.65003664 2.8669925 0.57552876 0.639231994 0.8224108
The fold.change variable gives the ratio of the observed
variance of each genomic interval to its prior variance. Note that the
pval variable gives two-sided p-values.
Therefore, for the genomic intervals with small p-values, those
associated with a fold.change larger than 1 suggest
hypervariable ChIP-seq signals across samples, and the others suggest
lowly variable or so-called invariant ChIP-seq signals:
# Visualize the overall test results.
hist(res$pval, breaks = 100, col = "red")
plot(res, padj = 0.01)You can get one-sided p-values for identifying hypervariable ChIP-seq signals by
#> observed prior
#> 4 Inf
Compared with the genomic intervals occupied by all the ChIP-seq samples, those intervals occupied only by part of the samples should be associated with higher signal variability and, thus, tend to have more significant p-values:
n <- rowSums(norm[9:13])
x <- list(All = -log10(one.sided.pval[n == 5]),
Partially = -log10(one.sided.pval[n > 0 & n < 5]))
wilcox.test(x$All, x$Partially, alternative = "less")#>
#> Wilcoxon rank sum test with continuity correction
#>
#> data: x$All and x$Partially
#> W = 445213772, p-value < 2.2e-16
#> alternative hypothesis: true location shift is less than 0
In practice, you can also call hypervariable signals across groups of
ChIP-seq samples, by first using cmbBioCond() to integrate
the samples of each group into a reference profile (see also the section
of Combining Replicates and Using Local
Regression).
Here we give the standard workflow for performing hierarchical clustering on a set of ChIP-seq samples. We use all the H3K27Ac ChIP-seq samples as an example:
# Normalize all ChIP-seq samples once for all.
autosome <- !(H3K27Ac$chrom %in% c("chrX", "chrY"))
norm <- normalize(H3K27Ac, count = 4:8, occupancy = 9:13,
baseline = "pseudo-reference",
common.peak.regions = autosome)
# Construct a bioCond to group all the samples.
cond <- bioCond(norm[4:8], norm[9:13], occupy.num = 1,
name = "all")
# Fit an MVC by using local regression.
cond <- fitMeanVarCurve(list(cond), method = "local",
occupy.only = TRUE, args.lp = list(nn = 1))[[1]]#> During the local regression procedure:
#> After iteration 1: 97 (0.13%) outlier(s) detected
#> After iteration 2: 112 (0.15%) outlier(s) detected
#> After iteration 3: 116 (0.16%) outlier(s) detected
#> After iteration 4: 116 (0.16%) outlier(s) detected
#> Converged.
#> GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 1.3505179
#> GM12891_H3K27Ac_2.read_cnt 1.3832427 0.2790962
#> GM12892_H3K27Ac_1.read_cnt 1.1447463 0.8673543
#> GM12892_H3K27Ac_2.read_cnt 1.1442555 0.8925351
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_2.read_cnt
#> GM12892_H3K27Ac_1.read_cnt 0.8403184
#> GM12892_H3K27Ac_2.read_cnt 0.8474437 0.2623903
Note: distBioCond() quantifies the
distance between each pair of samples contained in the supplied
bioCond. Each distance derived by
distBioCond() could be interpreted as absolute
difference in signal intensity between two samples averaged across
genomic intervals. In the above example, the average fold change of
H3K27Ac ChIP-seq signal between the 1st and 2nd replicates of GM12891 is
about \(2^{0.2790962} \approx 1.2\),
while the average fold change between the 1st replicates of GM12891 and
GM12892 is about \(2^{0.8673543} \approx
1.8\). Technically, distBioCond() calculates a
p-norm distance for each pair of samples while using the
reciprocal of variance to weight each genomic interval. Suppose \(x_{i}\) and \(y_{i}\) represent the signal intensities of
interval \(i\) in two samples. \(w_{i}\) is the reciprocal of the variance
of interval \(i\). The function derives
the distance between the two samples by
\[ d = \sqrt[p]{\frac{ \sum_{i}w_{i}|y_{i} - x_{i}|^{p} }{ \sum_{i}w_{i} }} \]
By default, distBioCond() uses \(p=2\) and the "prior" method
to calculate the variance of each interval (type
?distBioCond for details).
In practice, you may want to use only the genomic intervals that are associated with hypervariable signal intensities across samples to perform clustering, as such intervals should be most helpful for distinguishing between samples:
# Select hypervariable genomic intervals.
cond <- estParamHyperChIP(cond)
res <- varTestBioCond(cond)
f <- res$fold.change > 1 & res$padj < 0.01
# The hierarchical structure among samples remains unmodified,
# but note the change of magnitude of the distances between cell lines.
d2 <- distBioCond(cond, subset = f, method = "prior")
d2#> GM12890_H3K27Ac_1.read_cnt GM12891_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_1.read_cnt 4.0412182
#> GM12891_H3K27Ac_2.read_cnt 4.0706951 0.3131988
#> GM12892_H3K27Ac_1.read_cnt 3.3901795 2.0668405
#> GM12892_H3K27Ac_2.read_cnt 3.3263697 2.0723909
#> GM12891_H3K27Ac_2.read_cnt GM12892_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_1.read_cnt
#> GM12891_H3K27Ac_2.read_cnt
#> GM12892_H3K27Ac_1.read_cnt 2.0365856
#> GM12892_H3K27Ac_2.read_cnt 2.0339763 0.2795365
You can also perform hierarchical clustering on groups of ChIP-seq
samples, by first using cmbBioCond() to integrate the
samples of each group into a reference profile (see also the section of
Combining Replicates and Using Local
Regression).
Here we provide a formal description of the statistical model designed in MAnorm2. Suppose \(X_{j}\) is an \(n \times m_{j}\) matrix recording normalized ChIP-seq signal intensities (by default, normalized signal intensities derived by MAnorm2 are normalized log2 read counts) at \(n\) genomic intervals for \(m_{j}\) samples belonging to group \(j\). Let \(X_{i,j}\) be a column vector representing the transpose of row \(i\) of \(X_{j}\). We assume
\[ X_{i,j}|\sigma^{2}_{i,j} \sim MVN(1\mu_{i,j}, (\gamma_{j}\sigma^{2}_{i,j})S_{i,j}) \\ \frac{1}{\sigma^{2}_{i,j}} \sim \frac{1}{f(\mu_{i,j})} \cdot \frac{\chi^{2}_{d_{0}}}{d_{0}} \]
Here \(MVN\) refers to the multivariate normal distribution. \(\mu_{i,j}\) and \(\sigma^{2}_{i,j}\) are two unknown scalars that parametrize the mean signal intensity of interval \(i\) in group \(j\) and the associated signal variability, respectively. \(1\) is a column vector of ones. \(\gamma_{j}\), termed variance ratio factor, is a scalar that quantifies the global within-group variability of group \(j\). \(S_{i,j}\), termed structure matrix, is an \(m_{j} \times m_{j}\) matrix designed for modeling precision weights of signal measurements from different samples as well as correlations among the measurements (by default, MAnorm2 simply sets each structure matrix to an identity matrix). \(f(\cdot)\) refers to an unscaled MVC common to different groups of samples and \(f(\mu_{i,j})\) is called the prior variance of interval \(i\) in group \(j\). \(d_{0}\), termed number of prior degrees of freedom, is a hyperparameter that assesses how well in general the variance of an individual interval could be predicted by its mean signal intensity. \(\chi^{2}_{d_{0}}\) refers to the chi-squared distribution with \(d_{0}\) degrees of freedom. For the convenience of devising statistical tests for identifying differential genomic intervals between groups of samples, we further assume that unscaled variances of non-differential intervals remain invariant across groups. Formally, we assume that \(\sigma^{2}_{i,j_{1}}\) equals \(\sigma^{2}_{i,j_{2}}\) with a probability of one (i.e., they refer to the same random variable) whenever \(\mu_{i,j_{1}} = \mu_{i,j_{2}}\). This assumption is consistent with the fact that \(\sigma^{2}_{i,j_{1}}\) and \(\sigma^{2}_{i,j_{2}}\) follow the same prior distribution on condition that \(\mu_{i,j_{1}} = \mu_{i,j_{2}}\).
Overall, the above model is similar to limma-trend (Sartor et al. 2006; Law et al. 2014), except that MAnorm2 allows for different global within-group variability between groups of samples.
To cite the MAnorm2 package in publications, please use
Tu, S., et al., MAnorm2 for quantitatively comparing groups of ChIP-seq samples. Genome Res, 2021. 31(1): p. 131-145.
If you have performed MA normalization with a pseudo-reference profile as baseline, or have employed a Winsorization-based robust parameter estimation framework, or have performed a hypervariable analysis, please cite additionally
Chen, H., et al., HyperChIP for identifying hypervariable signals across ChIP/ATAC-seq samples. bioRxiv, 2021: p. 2021.07.27.453915.
In devising the underlying statistical methods of MAnorm2, we have learned a lot from limma, limma-trend, voom, DESeq and DESeq2 (Smyth 2004; Sartor et al. 2006; Law et al. 2014; Anders and Huber 2010; Love et al. 2014). Special thanks to the authors of these fantastic tools.
We would also like to sincerely thank the following individuals, for their help and feedback on the MAnorm2 package:
Zhen Shao, Yijing Zhang, Mushan Li, Haojie Chen, Fengxiang Tan.
#> R version 4.6.1 (2026-06-24)
#> Platform: x86_64-pc-linux-gnu
#> Running under: Ubuntu 26.04.1 LTS
#>
#> Matrix products: default
#> BLAS: /usr/lib/x86_64-linux-gnu/openblas-pthread/libblas.so.3
#> LAPACK: /usr/lib/x86_64-linux-gnu/openblas-pthread/libopenblasp-r0.3.32.so; LAPACK version 3.12.0
#>
#> locale:
#> [1] LC_CTYPE=en_US.UTF-8 LC_NUMERIC=C LC_TIME=en_US.UTF-8
#> [4] LC_COLLATE=en_US.UTF-8 LC_MONETARY=en_US.UTF-8 LC_MESSAGES=en_US.UTF-8
#> [7] LC_PAPER=en_US.UTF-8 LC_NAME=C LC_ADDRESS=C
#> [10] LC_TELEPHONE=C LC_MEASUREMENT=en_US.UTF-8 LC_IDENTIFICATION=C
#>
#> time zone: Etc/UTC
#> tzcode source: system (glibc)
#>
#> attached base packages:
#> [1] stats graphics grDevices utils datasets methods base
#>
#> other attached packages:
#> [1] MAnorm2_1.2.2 rmarkdown_2.32
#>
#> loaded via a namespace (and not attached):
#> [1] gplots_3.3.0 cli_3.6.6 knitr_1.52 rlang_1.3.0 xfun_0.61
#> [6] KernSmooth_2.23-27 jsonlite_2.0.0 gtools_3.9.5 glue_1.8.1 statmod_1.5.2
#> [11] buildtools_1.0.0 htmltools_0.5.9 maketools_1.3.2 sys_3.4.3 sass_0.4.10
#> [16] locfit_1.5-9.12 scales_1.4.0 grid_4.6.1 caTools_1.18.4 evaluate_1.0.5
#> [21] jquerylib_0.1.4 bitops_1.1-0 fastmap_1.2.0 yaml_2.3.12 lifecycle_1.0.5
#> [26] compiler_4.6.1 RColorBrewer_1.1-3 lattice_0.23-1 farver_2.1.2 digest_0.6.39
#> [31] R6_2.6.1 bslib_0.12.0 tools_4.6.1 cachem_1.1.0